OEM MODULES AND SOLUTIONS
OEM MODULES AND SOLUTIONS
Our board is developed to exploit the maximum potential of the 5 Series sensors, ensuring optimal performance within the harsh environments of flue gas analysers, combustion efficiency monitors and SCR DeNOX System Monitor. The concentrator completes the system allowing total flexibility in terms of the number of connected sensors and the type of outputs. The Modbus TCP/IP connection allows integration with the latest industrial control units, while the 4-20mA outputs are better suited to traditional systems. Digital communication allows total control of every sensor parameter, as well as managing all sensor calibration phases.
5 SERIES COMPATIBILITY
The board is compatible with all three and four electrodes 5 Series toxic gas sensors.
DIGITAL OUTPUT
The individual board has a digital output to connect to the concentrator or to be integrated into the customer's electronics.
FLEXIBILITY
We develop a concentrator that can accepts up to 6 sensors as input which can be read via MODBUS TCP/IP.
ANALOGUE OUTPUT OPTION
To ensure that the system is also compatible with analogue systems, the concentrator has a 4-20mA output for each sensor.
CALIBRATION
Through the concentrator it is possible to calibrate the sensor in zero and span.
| 5 SERIES PORTFOLIO | |||
| Measurement technology |
3 and 4 Electrode Electrochemical |
||
| Measurement range |
From 0 up to 40.000ppm depending on gas and model |
||
| Type of gas |
CO | ||
| NO | |||
| NO2 | |||
| SO2 | |||
| other | |||
| Board Specifications | |||
| Power Supply |
10-30 VDC |
||
| Digital Output |
ModBus TCP/IP |
||
| Temperature range |
-20°C to +50°C |
||
| Resolution |
Typical 1 ppm for all kind of sensors |
||
| Special function |
autoconfiguration |
||
| CONCENTRATOR |
|
| No. of connected sensors | Up to 6 |
| Power supply |
10-30VDC |
| Digital output | Modbus TCP/IP |
| Analogue output | Up to 6 4-20mA |
| Temperature range | 0-50°C |
| Resolution | Typical 1 pmm for all kind of sensors |